Product Code: MARHPAT400
In Stock
The HPAT400 is an easy-to-use, battery-powered, hand-held PAT tester with simple one-button test selection. Its lightweight portable design makes it ideal for testing in all locations whether under a desk or testing a wall-mounted monitor.
A single button press activates either a full Class I, Class II or lead test without any further interaction required by the user, unless a failure is encountered. The display has clear PASS/FAIL indicators but does not display test values. Simple connection diagrams are permanently shown on the case body making it easy to start testing straight away. The HPAT400 delivery contents include an extension lead adaptor, an earth bond probe with clip, 6xAA alkaline batteries and a "TEST & GO" carry case with separate pocket for accessories.
Martindale HPAT400 Pass/Fail PAT Tester Specifications | |
Earth Continuity | |
Test voltage | 4V DC (into open circuit) |
Test current | 200mA DC (into short circuit) |
Accuracy | ± 0.03Ω |
Pass Limits | Lead ≤ 0.20 Ω = PASS |
Class I ≤ 0.20 Ω = PASS | |
Insulation | |
Fixed voltage | >500V DC at 1mA (< 625V DC into open circuit) |
Test current | 1.5mA (into short circuit) |
Accuracy | ± 0.1MΩ |
Pass limits | Lead: ≥ 1.0 MΩ |
Class I: ≥ 1.0 MΩ | |
Class II: ≥ 2.0 MΩ | |
Fuse Check | |
Test voltage | 4V DC (into open circuit) |
Test current | 200mA DC (into short circuit) |
Pass level | >2mA |
General | |
Overload protection | 300V AC/DC |
Protection class | IP20 |
Safety | Complies to BS EN 61010-1 |
Temperature Range | -10 to 40°C, non-condensing |
Batteries | 6 x AA alkaline batteries |
Battery Life | minimum 600 complete tests |
Auto Power Down | After 10 minutes of inactivity, or when battery low |
Dimensions | 90 x 210 x 54mm |
Weight | Approx 700g (including batteries & leads) |
UK Mainland | Order by 2pm for Next Day Delivery* |
---|---|
Under £25.00 | £4.50 |
Over £25.00 | FREE |
UK Highlands & Islands | Order by 2pm for Next Day Delivery* |
---|---|
Under £80.00 | £15.00 |
Over £80.00 | FREE |