Take measurements on your 1500 V dc systems, safely

1500 V DC systems are here. Now you can test these new installations with the only clamp meter designed for the task – the Fluke 393 FC CAT III 1500 V true-rms clamp meter. The world’s only CAT III 1500 V current clamp the 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is designed for technicians who work in DC environments up to 1500 V: solar arrays, wind power, electric railways, data centres battery banks for uninterruptible power supplies.
The clamp will measure up to 1500 V DC, 1000 V AC, and up to 999.9 A DC or AC through the clamp jaw. The included iFlex flexible current probe extended ac current measurements up to 2500 amps. This clamp has a thin jaw, giving you access to cables in crowded combiner boxes. Test leads are designed with your work in mind, and are also rated to CAT III 1500 V.

Fluke 393FC Comes Supplied With:

• Fluke 393 FC CAT III 1500 V TRMS clamp meter
• Test leads, CAT III 1500 V rated, right angle plugs, with safety caps
• iFlex 18-inch flexible current probe
• TPAK magnetic hanging strap
• Premium carrying case
• 3-year warranty


The 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is an industrial clamp meter designed for solar photovoltaic (PV) installation technicians and maintenance professionals who work in high voltage dc environments.
Safely connect the MC4 test leads to the clamp meter to validate voltage and current from individual panels or a series of panels in a PV array. 

Key Features:

  • The world’s first and only clamp meter with a CAT III 1500 V safety rating.
  • 1500 V CAT III insulated test leads specifically designed for use in 1500 V dc environments.
  • Visual Continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments
  • Plus more. A thin jaw to work in crowded combiner boxes. IP54 rating for use outdoors. Fluke Connect™ software to record, analyze and share results.
  • DC power measurement, showing readings in kVA
  • Audio Polarity indicator helps prevent accidental mis-wires
  • Logging and reporting of test results via Fluke Connect software
  • When measuring ac current the included iFlex flexible current
    probe gives you unparalleled access to cable is tight spaces.
    The iFlex probe can be twisted through extremely small spaces
    and provide accurate current measurements.

Fluke Connect:

Fluke_Connect

MEASURE SAFELY
CAT III 1500 V rated clamp meter
VERSATILE CLAMP JAW
Thin jaw for access to cables in crowded combiner
boxes, able to clamp around multiple cables
IP54 RATED
Work outdoors in dusty or damp conditions
MORE FUNCTIONS, AUTOMATIC SAFEGUARDS
Work efficiently with DC power measurement,
audio polarity and visual continuity

Fluke 393 FC TRMS Clamp Meter Technical Specification
General specifications
Maximum voltage between any terminal and earth ground 1000 V AC
1500 V DC
Batteries 2 AA IEC LR6 alkaline
Display Dual display with backlight
Automatic power off 20 minutes
Electrical specifications
Accuracy Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to  28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature coefficients Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
AC current: jaw  
Range 999.9 A
Resolution 0.1 A
Accuracy 2 % + 5 digits (10 Hz to 100 Hz)
2.5 % + 5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz) 2.5 @ 600.0 A
3.0 @ 500.0 A
1.42 @ 999.9 A
Add 2 % for C.F. >2
AC current: flexible current probe  
Range 999.9 A
2500 A
Resolution 0.1 A (≤999.9 A)
1 A (≤2500 A)
Accuracy 3 % RD + 5 digits (10 Hz to 500 Hz)
Crest Factor (50/60Hz) 2.5 @ 1400 A
3.0 @ 1100 A
1.42 @ 2500 A
Add 2 % for C.F. >2
Position sensitivity  
Distance from Optimum i2500-10 Flex i2500-18 Flex Error
A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5 %
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0 %
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
 
DC current
Range 999.9 A
Resolution 0.1 A
Accuracy 2 % RD + 5 digits[1]
[1]When using the  ZERO  function to compensate for offsets.
AC voltage  
Range 600.0 V
1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1 % RD + 5 digits (20 Hz to 500 Hz)
DC voltage
Range 600.0 V
1500 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1500 V)
Accuracy 1 % RD + 5 digits
mV dc  
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1 % RD + 5 digits
Amps frequency: jaw  
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % RD + 5 digits
Trigger level 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Amps frequency: flexible current probe  
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % RD + 5 digits
Trigger level 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Voltage frequency  
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % RD + 5 digits
Trigger level 5 Hz to 20 Hz, ≥5 V 20 Hz to 100 Hz, ≥5 V
100 Hz to 500 Hz, ≥10 V
DC power  
Range 600.0 kVA (600.0 V dc range)
1500 kVA (1500 V dc range)
Resolution 0.1 kVA
1 kVA
Accuracy 2 % RD + 2.0 kVA
2 % RD + 20 kVA
Resistance  
Range 600.0 Ω
6000 Ω
60.00 kΩ
Resolution 0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
0.01 kΩ (≤60.00 kΩ)
Accuracy 1 % RD + 5 digits
Capacitance  
Range 100.0 μF
1000 μF
Resolution 0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy 1 % RD + 5 digits
Inrush trigger level 5 A
Mechanical specifications
Size (L x W x H) 281 mm x 84 mm x 49 mm
Weight (with batteries) 520 g
Jaw opening 34 mm
Flexible current probe diameter 7.5 mm
Flexible current probe cable length (head to electronics connector) 1.8 m
Environmental specifications  
Operating temperature -10 °C to 50 °C
Storage temperature -40 °C to 60 °C
Operating humidity Non-condensing (<10°C)
≤90 % RH (at 10 °C to 30 °C)
≤75 % RH (at 30 °C to 40 °C)
≤45 % RH (at 40 °C to 50 °C)
Operating altitude 2000 m
Storage altitude 12,000 m
Ingress Protection (IP) Rating  
Electromagnetic Compatibility (EMC)  
International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromag- netic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC) Class A equipment (Industrial Broadcast and Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in busi- ness environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety  
General IEC 61010-1, Pollution Degree 2
Measurement IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
Wireless radio  
Radio frequency certification FCC ID: T68-FBLE, IC: 6627A-FBLE
Wireless radio frequency range 2400 MHz to 2483.5 MHz