Detailed Description

5th Edition and BE EN50699 Compliant

The Apollo 500+ features a comprehensive range of electrical safety tests with user-configurable test sequences and checklists for PAT, PPM, and PPE. It has storage for up to 10,000 test records and is compatible with our Seaward PATGuard 3 software for record-keeping and reporting.

Key Features:

  • Store up to 10,000 appliance records
  • Upload data for faster retesting
  •  Ability to use (2D) QR codes
  • Built-in electrical risk assessment tool with suggested retest period calculator
  • User configurable tests- for non-electrical tests and inspections e.g. fire
    extinguishers and PPE



The Apollo 500+ Comess Supplied With:

  • 1x test lead and probe with crocodile clip
  • 0.5m IEC lead
  • Mains power lead
  • USB download cable
  • Quick start guide
  • UKAS calibration certificate
  • 30-day free trial of PATGuard 3 software
  • 2 years warranty (subject to terms and conditions, available at www.seaward.co.uk/warranty24)

Why buy the new Apollo+ Series?

  • Large on-board storage
  • High-definition colour display
  • Remote data transfer via hotspot to mobile device from field to office
  • Fixed appliance (point-to-point) testing
  • User configurable tests- for nonelectrical tests and inspections
    e.g. fire extinguishers and PPE

Overview:

The Apollo 500+ is a great value PAT tester with a comprehensive range of tests, advanced data transfer and storage features. It also has a built-in electrical risk assessment tool to suggest inspection and test frequencies.

With a new processor, testing is now faster and more efficient than ever before, and our new Wifi Hotspot feature means it has never been easier to get results back to your office via your mobile device.

Designed to enable simple, professional and fast PAT testing, with a large memory to store up to 10,000 test records. Great for high volume testing, or if you are retesting a large number of appliances on a regular basis.

For faster and more efficient retesting, the Apollo 500+ can be used with Seaward’s PATGuard 3 software to upload equipment details from your existing database, saving time on data entry in the field.

Printing Seaward QR barcodes, using the Test n Tag Elite 2 printer, enables you to store equipment details on the label, making retesting faster even if data has not been uploaded to the tester.

Electrical Test Functions:

  • Low current earth continuity guaranteeing accurate measurements
  • User configurable tests - for non-electrical tests and inspections e.g. fire extinguishers and PPE
  • IEC lead test
  • Protective conductor current
  • Point-to-point measurement (Rpe & IR)
  • Built-in electrical risk assessment tool with suggested retest period calculator
  • Touch current
  • Load power/current
  • Alternative leakage current
  • RCD test
  • Power socket test

Which Seaward Apollo PAT Tester is right for me?

General Features 600+ 500+ 400+
Battery & mains powered
Colour screen & QWERTY keypad
Large internal memory up to 50,00 records and 2,000 photos up to 10,00 records up to 2,000 records
Bluetooth scanner & printer compatible
Password controlled user accounts  
Set up multiple user accounts with varying levels of privileges  
Clone facility to set up multiple testers  
Checkbox supplied as standard  
Test Inspection Features 600+ 500+ 400+
Auto-increment asset ID  
PAT Setup option to allow for custom menus  
Enter asset description after test using keypad or barcode scanner
Comprehensive electrical safety test features
Point to point measurement (Rpe & IR) Optional accessory required
User configurable electrical test/visual inspection sequences 100 100 25
User set sites & locations 100 100  
Risk based retest period calculator  
User definable comments lines against test records 4 5  
Configurable checklists for any workplace test or inspection (user tests)  
On-board camera    
Universal risk assessment    
Health & safety certificates    
Data Transfer 600+ 500+ 400+
1D and 2D Scanner connectivity Reads 1D data only
Read QR code (2D) labels with 2D scanner  
RFID reader connectivity    
Print Pass & Fail labels with 1D barcode
Print Pass & Fail labels with QR code (2D)  
Add your company logo to labels (on large 1D labels only)  
Select from various label formats to print 6 6 6
Download to PC via USB cable
Data Transfer via USB flash drive    
Filter results to be downloaded
Upload previous results to tester for retest  

PATGuard 3 Software

PATGuard 3 is the ultimate PAT testing software with health and safety reporting. Not only does it offer fast and comprehensive record management, but it also gives you the ability to record any workplace test or inspection, auto-schedule the next tests, and create invoices & reports for clients.

Seaward Apollo 500+ Technical Specification
Earth Continuity (Rpe)
Test Current +/- 200mA DC
Measurement Range 0.05Ω to 19.99Ω
Pass Value User defined
IEC Lead Test
Test Voltage 5VAC nominal
Test Live / Neutral Checks for o/c, s/c and crossed polarity
Touch Current
Test Voltage Supply voltage, maximum load current 16A
Measurement Range 0.10mA to 5mA
Pass Value User defined
Substitute (Alternative) Leakage Current
Test Voltages >25VAC <50VAC
Measurement Range 0.20mA to 19.99mA
Pass Value User defined
Power Socket Test
Voltage Range 207V – 253VAC
Indicates configuration of voltage potential:- Line potential phase to earth
Line potential phase to neutral Line potential neutral to earth
Insulation Resistance (IR)
Test Voltage 500V / 250VDC @ 1mA nominal
Measurement Range 0.10MΩ to 19.99MΩ
Pass Value User defined
Protective Conductor Current/Load
Test Voltage Supply voltage, maximum load current 16A
Measurement Range 0.25mA to 19.99mA
Pass Value User defined
Load Power/Current
Test Voltage 230V +10%, -15%, maximum load current 16A
Test Duration Programmable up to a maximum of 240s
Measurement Range 0.50A to 16.0A
RCD Test
Test Voltage 230V +10%, -15%
Test Current 30mA / 150mA rms sinusoidal
Display Range 0ms to 2000ms
Test Method Internal isolation to avoid tripping distribution board RCD
General
Memory size up to 10,000 records
Weight 1.5kg
Dimensions 230mm x 150mm x 100mm
Power Source Mains or rechargeable battery pack
Supported Printers Test n Tag Pro (339A980)
Test n Tag Elite 2 (339A989)
UK Mainland Order by 2pm for Next Day Delivery*
Under £25.00 £4.50
Over £25.00 FREE

UK Highlands & Islands Order by 2pm for Next Day Delivery*
Under £80.00 £15.00
Over £80.00 FREE