Megger PAT420 Portable Appliance Tester 1000-752

Product Code: MEG1000-752

Price
£1350.00 ex. VAT £1620.00 inc. VAT

In Stock


Add To Favourites
Detailed Description

Three new PAT testers with full database functionality based on the well received PAT300 series. The PAT 400 series introduces a new level of convenience and speed to PAT testing using onboard test results.

Key Features: 

■ Vast on-board memory to keep you the job longer
■ Continuous operation, no need to stop and wait for the tester to cool down
■ Instant re-start as you move from room to room testing
■ Soft keys to speed you through the testing process
■ Full PAT testing including RCD testing
■ Most productive tester in its class

FREE PAT testing accessories

Overview:


PAT410 perfect for those content to bond test solely at 200 mA, The smallest, lightest of the PAT400 series weighs only 2.7 kg.

PAT420 offers bond testing at all three currents, 200 mA, 10 A and 25 A and 230 V and 110 V operation. This tester is the choice of those who are full-time industrial or commercial PAT testers.

PAT450 in addition to the three bond test and 230 V and 110 V operation this tester offers 1.5 kV and 3.0 kV flash testing making the perfect tool for hire and repair workshops.

There is a legal requirement for any landlord, employer or owner of a place of work or public place, to ensure that all electrical equipment accessible by tenants, employees or the public is maintained in a safe condition, and an acceptable method of ensuring this is by routine electrical testing. This can be performed by electrical contractors, specialist PAT testing organisations, maintenance departments, or facilities management companies.

The PAT400 range is suitable for performing portable appliance testing in locations such as hotels, public houses, schools, colleges, nurseries, shops, offices, theatres, banks, restaurants, cafés, sports and leisure facilities, cinemas, factories and hair salons etc. where high volume testing requires that accurate records may be difficult to maintain, or aided by, on-board memory and download to management software. The PAT450 is particularly suitable for use in tool-hire shops where equipment is routinely tested prior to hire, or service workshops where deep disassembly is routine, and will perform a flash test in addition to standard PAT tests.

 

Megger PAT420 Portable Appliance Tester
Electrical Supply Range 230V ±10 @ 50/60Hz
110V ± 10% + 110V ±10% @50Hz
Bond Test (10A and 25A)  
Open Circuit Voltage 9V AC ±10% ± 0.1V
(supply: 230V 50Hz)
Earth Bond Resistance Accuracy ±5% ± 3 digits (0 to 0.49Ω)
±5% ±5 (0.5 to 0.99Ω)
Display Range 0 to 1.99Ω
Continuity Test (200mA)  
Continuity Test Voltage 9V AC ± 10% ± 0.1V
(supply: 230V 50Hz)
Continuity Resistance Accuracy ±5% ± 3 digits (0 to 0.49Ω)
±5% ± 5 digits (0.5 to 0.99Ω)
Continuity Resistance Resolution 10mΩ (1 to 19.99Ω)
Display Range 0 to 19.99Ω
Insulation Test (250V and 500V)  
Insulation Resistance Accuracy (230V) ±2% ±5 digits (0 to 19.99MΩ)
±5% ± 10 digits (20 to 99.99MΩ)
Insulation Resistance Resolution 0.01MΩ
Display Range 0 to 99.99MΩ
Substitute Leakage Test  
Test Voltage and Frequency 40V AC ±10% nominal mains frequency
Leakage Current Accuracy ±5% ± 5 digits
Leakage Current Resolution 0.01mA
Display Range 0 to 19.99mA
Differential Leakage Current  
Test Voltage Nominal mains 110/230V AC
Test Frequency Nominal mains 50/60Hz
Differential Leakage Current Accuracy ±5% ± 0.05mA (1.0mA to 9.99mA)
±5% ± 0.1mA (0.1mA to 0.99mA)
Resolution 0.01mA
Display/Measurement Range 0.10mA to 19.99mA
Test Duration User-selectable from 1 sec
10 sec to infinity
Touch Current Test  
Test Voltage and Frequency Nominal mains supply
Touch Current Accuracy ±5% ± 5 digits
Touch Current Resolution 0.01mA
Display 0 to 10mA
Operational Test  
Test Voltage and Frequency Nominal mains supply
VA Rating 230V 3700VA
110V 1800VA
VA Accuracy ±5% ± 10 digits (0 to 99VA)
±5% ± 50 digits (100VA to 999VA)
±5% ± 100 digits (1000VA to 3700VA)
Resolution 1VA (0 to 3700VA)
Display Range 0 to 3990VA
Extension Lead Test  
Tests Performed Bond, insulation and polarity
Polarity Test Voltage 12V
Polarity checks Lead ok
Live neutral S/C
Live neutral reversed
Live/neutral O/C
Portable RCD Test  
Test Voltage and Frequency Nominal mains supply
Test Current Accuracy -8% to -2% (1/2 x I)
+2 to +8% (1 x I, 5 x I)
Trip Time Accuracy ±1% ± 5 digits
Trip Time Resolution 0.1ms
Display Range 0 to 1999ms (1/2 x I)
0 to 300ms (1 x I)
0 to 40ms (5 x I)
Fuse Test  
Test Voltage 3.3V
Warning Audible beep if fuse is OK
Environmental  
Operating Temperature -10 to 50°C
Storage Temperature -20 to 60°C
Humidity 90% RH @ -10 to 30°C
75% RH @ +30 to 50°C
Maximum Altitude 2000m
Ingress Protection IP40
Other  
Weight 4.4kg
Dimensions 180 (H) x 255 (W) x 320mm (L)
Safety IEC 61010-1: CAT II 300V
EMC IEC 61326-1: 2006
IEC 61326-2-2: 2005