Product Code: TSIPH731STA
Available In 3-7 Days
The ProHood Capture PH731-STA Hood Kit is a multipurpose electronic air balancing instrument primarily used for efficiently taking direct air volume readings at diffusers and grilles, complete with a trolley and smart tablet.
This instrument comes complete with the manufacturer’s calibration certificate. Please be aware that these certificates are generic and may also be time lapsed. If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply.
Combine this with the use of the Capture Hood Stand—turning one person balancing into a reality to:
* TSI has the discretion to change the brand and model of tablet at any time.
It features a detachable micromanometer which can be used with optional probes for increased flexibility in multiple measurement applications.
Offering durable, trouble-free operation, this lightweight, ergonomically designed capture hood kit saves time and money by combining multiple measurement tools into one package. The ProHood Capture PH731 helps you create healthy and energy efficient environments while meeting local codes, guidelines and regulations for ventilation systems.
Velocity Range | |
Pitot probes | 0.125 to 78 m/s (25 to 15,500 ft/min) |
Air flow probe | 0.125 to 12.5 m/s (25 to 2,500 ft/min) |
Velocity matrix | 0.125 to 12.5 m/s (25 to 2,500 ft/min) |
Accuracy | ±3% of reading ±0.04 m/s (±7 ft/min) at velocities >0.25 m/s (50 ft/min) |
Units | m/s, ft/min |
Resolution | 0.01 m/s (1 ft/min) |
Pressure | |
Differential pressure | ±3735 Pa H2O (±15 in.); 37.5 kPa H2O (150 in.), maximum safe operating pressure |
Absolute pressure | 356 to 1016 mm Hg (15 to 40 in. Hg) |
Accuracy | ±2% of reading ±0.025 Pa H2O (±0.0001 in.) static and differential; ±2% of reading absolute |
Units | in. H2O, in. Hg, Pa, hPa, kPa, mm Hg, cm Hg, mm H2O, cm H2O |
Resolution | n 0.001 Pa H2O (0.00001 in.) static and differential; 1 mm Hg (0.01 in. Hg) absolute |
Volume | |
Range | 42 to 4250 m3/h (25 to 2,500 ft3/min) capture hood, supply and return |
Accuracy | ±3% of reading ±12 m3/h (±7 ft3/min) at flows >85 m3/h (>50 ft3/min) |
Units | m3/h, ft3/min, l/s, m3/min |
Resolution | 1 m3/h (1 ft3/min) |
RH | |
Range | 5 to 95% RH (temperature/RH probe) |
Accuracy | ±3% RH |
Resolution | 0.1% RH |
Temperature | |
Sensor in base | 4.4 to 60°C (40 to 140°F) |
Temperature/RH probe | -10 to 60°C (14 to 140°F) |
Accuracy | ±0.3°C (±0.5°F) |
Units | °C, °F |
Resolution | 0.1°C (0.1°F) |
Instrument Temperature Range | |
Operating | 4.4 to 60°C (40 to 140°F) |
Storage | -20 to 71°C (-4 to 160°F) |
Statistics | min, max, average and sum |
Data Storage | 25,500 samples, time and date stamped |
Logging Interval | User selectable |
Response Time | 2 to 8 seconds, differential pressure sensor |
Power Requirements | Four AA-size cells or AC adapter |
Physical Characteristics | |
Dimensions (micromanometer only) | 18.8 cm x 11.4 cm x 5.8 cm (7.4 in. x 4.5 in. x 2.3 in.) |
Weight with Batteries | PH730 0.5 kg (17 oz.) PH731 3.4 kg (7.4 lb.) |
Pressure Connection | 6.35 mm (1/4 in.) OD straight ports with barbed ends for use with 4.76 mm (3/16 in.) ID flexible tubing |
UK Mainland | Order by 2pm for Next Day Delivery* |
---|---|
Under £25.00 | £4.50 |
Over £25.00 | FREE |
UK Highlands & Islands | Order by 2pm for Next Day Delivery* |
---|---|
Under £80.00 | £15.00 |
Over £80.00 | FREE |
Price £1074.00 £895.00
Available In 3-7 Days