Product Code: MARET6000PR
Available In 3-7 Days
Martindale are pleased to announce the launch of two new special kits designed to give electricians and installers a great bundle of essential tools for installation testing and troubleshooting.
The ET6500PROMO - Advanced Installation & Safety Kit and ET6000PROMO - Installation & Fault Finding Kit include the latest Martindale ET6500 and ET6000 multifunction installation testers, plus additional test equipment - completely free.
This is a limited-time offer set to run until April 30th 2026 and is subject to availability.
The Installation & fault finding kit is designed to give electricians and installers a great value bundle of test equipment. Ideal for installation testing and general electrical troubleshooting.
Available for a limited period, the kit includes the Martindale ET6000 18th edition installation tester, an advanced socket tester for first line testing and earth loop checking, plus a handy fuse finder to help identify the right circuit, fuse and connections.
The Martindale Installation & Fault Finding Kit includes a range of essential tools for testing and troubleshooting electrical circuits. Including the ET6000 Multifunction Installation Tester, an EZ165 advanced socket tester for first line testing and earth loop checking, plus a handy FD500 fuse finder with transmitter to help identify the right circuit, fuse and connections.
The Martindale Advanced Installation & Safety Kit includes a top-of-the-range ET6500 18th Edition Multifunction Installation Tester complete with EV adaptor, plus a VT25 Voltage Tester and matched PD690SRD proving device, ideal for checking voltage is present in a circuit and taking basic electrical measurements. To aid with safety, it is also supplied with a Martindale LOKKIT1 lock-off kit, and a voucher for free access to an online Lock-out, Tag-out introductory course (one participant).
ET6000PROMO - Installation & Fault Finding Kit Includes:
ET6500PROMO Advanced Installation & Safety Kit Includes:
is designed to give electricians and installers a great value bundle of test equipment. Ideal for installation testing and general electrical troubleshooting. Available for a limited period, the kit includes the Martindale ET600018th edition installation tester, a free advanced socket tester for firstline testing and earth loop checking, plus a free handy fuse finder to help identify the right circuit, fuse and connections.
The ET6000 Multifunction Tester can perform all the measurements required for the verification of electrical installations,in accordance with the latest 18th Edition Wiring Regulations. It has reliable high-current and non-trip loop tests together with a high level of input protection and a CAT IV safety rating.The EZ165 Socket Tester can detect 28 socket wiring fault conditions and checks mains voltage levels. In addition, it verifies the earth wiring by carrying out a non-trip earth loop test.Martindale’sFD500 Circuit Breaker and Fuse Finder Kitfindswhich fuse or breaker controls a circuit. It also enables tracing from socket to socket to fuse or circuit breaker on a circuit, easily distinguishing the appropriate circuit, even on a crowded fuse board.
| Voltage | 0V - 500V |
|---|---|
| Frequency | 10Hz - 499Hz |
| Complies with | BS EN 61010-1 CAT III 600V CAT IV 300V BS EN 61557 BS 57671:2018 18th Edition BS EN 61326-1 |
| Dimensions | 250mm x 107mm x 135mm |
| Weight | 1.3kg approx. (excl. batteries) |
| Insulation Resistance | Nominal voltages: 50, 100, 250, 500 and 1,000V DC |
| Continuity Resistance | Low R (200mA) |
| RCD Testing | Nominal residual currents: 10mA / 30mA / 100mA / 300mA / 500mA RCD type: A, AC, G, S |
| Other Features | Systems: TN, TT Optional rechargeable batteries |
| Nominal Operating Voltage | 230V AC rms ± 10% |
|---|---|
| Operating Frequency | 50Hz |
| Power Consumption | <2.5W |
| Power | from the main socket under test |
| Non-trip Earth Loop Impedance Ranges | 0 - 1.7 - 5 - 10 - 100 - 200 - 500Ω |
| Earth Loop Threshold Accuracy | ± (10% + 0.3Ω) *Measurement accuracy can be affected by highly inductive or capacitive loads distributed on the supply (see section 3.3.6). |
| Voltage Low Indication | <195V ± 5% |
| Voltage High Indication | >270V ± 5% |
| Earth Neutral Voltage High Indication | >30V nominal |
| Open Earth Indication | >500Ω ± 10% |
| Dimensions | 65 x 80 x 59mm |
| Weight | approx. 93g |
| Environment | For indoor use only |
| Temperature (Operating & Storage) | -10°C to 40°C, at max.60% RH |
| Altitude | up to 2000m |
| Pollution Degree | 2 |
| Safety | Conforms to BS EN 61010-1, CAT II 300V Class II, double insulation |
| EMC | Conforms to BS EN 61326-1 |
| Transmitter | |
|---|---|
| Voltage Rating | 230V |
| Frequency Range | 30 - 70Hz |
| Switching Frequency | Approx. 5Hz |
| Transmission Pulse Width | Approx. 1.7μS |
| Transmission Pulse Amptitude | 20A max. |
| Temperature Range | -10°C to 40°C at max 60% RH |
| Dimensions | Approx: 65 x 65 x 46mm |
| Weight | 60g |
| Earth Leakage | Nil |
| Power Supply | From mains |
| Power Consumption | Approx. 1W |
| Overvoltage Category | Cat III/300V |
| Pollution Degree | 2 |
| Protection Class | IP20 |
| Transmitter | |
| Tracing Depth for Fuse Assignment | Approx. 0 - 10cm, depending on local conditions |
| Sensitivity Setting | via on/off potentiometer |
| Temperature Range | -10°C to 40°C at max 60% RH |
| Dimensions | 160 x 55 x 30mm |
| Weight | Approx. 135g (including battery) |
| Protection Class | IP20 |
| Power Supply | 9V battery, MN1604/PP3, IEC 6LA61 (alkaline only) |
| UK Mainland | Order by 2pm for Next Day Delivery* |
|---|---|
| Under £25.00 | £4.50 |
| Over £25.00 | FREE |
| UK Highlands & Islands | Order by 2pm for Next Day Delivery* |
|---|---|
| Under £80.00 | £15.00 |
| Over £80.00 | FREE |