Product Code: FLUT6-600UK
In Stock
The Fluke T6-600, now you can measure voltage without test leads. Be safer, faster, more efficient. And be everywhere, testing where it used to be impossible.
*Important Calibration Information:
This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘traceable calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.
Where calibration of an instrument is possible, we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a full traceable calibration certificate produced in our laboratory and applied with your details as required.
The successor to the hugely successful Fluke T5 electrical tester, the T6-600 and T6-1000.
Measure voltage … without test leads
FieldSense technology lets you slide the open fork over a conductor and see the voltage level.1
Measure voltage up to 600 V ac through the open fork, without test lead contact to live voltage.+ Without opening covers or removing wire nuts. On wires up to AWG 4/0 (120 mm2), carrying as much as 200 A. It will change your job. Safer. Faster. Easier.
1 Requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations.
+ Voltage measurement requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations.
Fluke T6-600 Electrical Tester |
|||||
Function | Requires |
T6-600 Range |
T6-1000 Range |
Resolution | Accuracy |
FieldSense AC Voltage | No | 1-600V | 1-1000V | 1V | ±(3 % + 3 counts) [2] [3] 45 Hz - 66 Hz |
FieldSense AC Current | No | 0.1-200A | 0.1-200A | 0.1A | ±(3 % + 3 counts) 45 Hz - 66 Hz |
FieldSense Frequency (Hz) | No | N/A | 45-66 Hz | 1Hz | ±(1 % + 2 counts) [3] |
Volts AC | Yes | 1-600V | 1-1000V | 1V | ±(1.5 % + 2 counts) 45 Hz - 66 Hz |
Volts DC | Yes | 1-600V | 1-1000V | 1V | ±(1 % + 2 counts) |
Resistance |
Yes Yes Yes |
2000 Ω
|
2000 Ω 20.00 kΩ 100.0 kΩ |
1 Ω 0.01 kΩ 0.1 kΩ |
±(1 % + 2 counts) ±(1 % + 2 counts) ±(1 % + 2 counts) |
Safety (measurement category) | 600 V CAT III | 1000 V CAT III 600 V CAT IV | |||
General Specification |
|||||
Calibration | 1-year calibration cycle | ||||
Dimensions | 61.1 mm x 259.3 mm x 43.8 mm | ||||
Operating Temperature | -10 °C to +50 °C (14 °F to 122 °F) | ||||
Storage Temperature | -30 °C to +60 °C (-22 °F to +140 °F) | ||||
Operating Altitude | 2,000 m (6,562 feet) | ||||
Storage Altitude | 10,000 m (32,808 feet) | ||||
Relative Humidity |
0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F) 0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F) 0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F) |
||||
Battery Type and Life | 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense | ||||
Temperature Coefficient | 0.1 x (specified accuracy) / °C for <18°C or >28 °C (< 64.4 °F or > 82.4 °F) | ||||
Safety | IEC/EN 61010-1, IEC/EN 61010-2-033: Pollution Degree 2 | ||||
Electromagnetic Environment | IEC/EN 61326-1: Portable | ||||
Fork Opening | 17.8mm | ||||
Weight | 0.35 kg (0.78 lb) |
UK Mainland | Order by 2pm for Next Day Delivery* |
---|---|
Under £25.00 | £4.50 |
Over £25.00 | FREE |
UK Highlands & Islands | Order by 2pm for Next Day Delivery* |
---|---|
Under £80.00 | £15.00 |
Over £80.00 | FREE |