Fluke 707 Loop Calibrator

Product Code: FLU707

Price
£959.95 ex. VAT £1151.94 inc. VAT

In Stock


Add To Favourites
Detailed Description

Key Features:

  • One handed user interface with 'Quick Click' detented knob
  • mA sourcing, simulation and measurement
  • 0.015% accuracy and 0.001 mA resolution
  • Simultaneous mA and % of span display
  • Selectable step or ramp outputs
  • 24 V Loop supply with mA measure, including 250Ω HART resistor
  • 0-28 VDC measurement to check Loop Voltage
  • Easy battery exchange without opening the case
  • Compact case with separate protective holster
  • Three year warranty
  • NIST Traceable Certification

The fastest, one-handed tool for loop checks

The Fluke 707 Loop Calibrator is a high performance solution for calibration, repair and maintenance of current loops. The new 'Quick Click' knob making it extremely fast and easy to use. It features:

Fluke 707 comes Supplied With:

  • AC70A Alligator Clips
  • C10 protective yellow holster with Flex-Stand™
  • Instruction sheet
  • TL75 safety-designed test lead set
  • NIST- traceable calibration report and data

 

This feature-rich solution combines the best features push-button and knob-base loop calibrator and offers:

  • Large display and simple, quick-click interface for easy one-handed operation.
  • Simultaneous mA and % readout for quick, easy interpretation of readings.
  • mA accuracy of 0.015%, superior to other loop calibrators in this price range.
  • 1 µA resolution for mA source, simulate and measure.
  • Push button 25% steps for fast, easy linearity checks.
  • 0-100% “span check” for fast confirmation of zero and span.
  • Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests.
  • 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
  • Measures V dc to 28 V.
  • Single 9V battery that is easily changed without braking calibration seal
  • 0 - 20 mA or 4 - 20 mA default start up modes.
  • Innovative output adjustment dial with 1 µA and 100 resolution.
  • HART ™ mode connects 250 Ω resistor in series with 24 V loop for compatibility with HART communicators.
Specifications
Current Measurement
Range:  0 to 24 mA
Resolution:  0.001 mA
Accuracy:  0.015% Rdg + 2 LSD
Current Sourcing
Range:  0 to 20 mA or 4 to 20 mA
Accuracy:  0.015% Rdg + 2 LSD
Drive Capability:  1200 Ω; 950 Ω at 20 mA in HART mode
Current Simulation
Range:  0 to 20 mA or 4 to 20 mA
Accuracy:  0.015% Rdg + 2 LSD
Ext. loop voltage requirement:  12-30 V
Loop Power
   While measuring mA, 24 V
Voltage measurement
Range:  0 to 28 V DC
Resolution:  1 mV
Accuracy:  0.015% Rdg + 2 LSD

UK Mainland Order by 2pm for Next Day Delivery*
Under £25.00 £4.50
Over £25.00 FREE

UK Highlands & Islands Order by 2pm for Next Day Delivery*
Under £80.00 £15.00
Over £80.00 FREE