Product Code: CHACA8331
Available In 3-7 Days
Measure all the necessary voltage, current, and power parameters for full diagnosis of an electrical installation. Capture and record all the parameters, transients, alarms, and waveforms simultaneously.
Designed for inspection and maintenance teams in industrial or administrative buildings, the Qualistar can provide a snapshot of the main electrical network quality characteristics. Easy to handle and precise, these instruments also offer a large number of calculated values and several processing functions.
Designed to cover all 600 V CAT IV and 1000 V CAT III applications in compliance with the IEC 61010 standard, the Qualistar+ range is divided up according to the functions provided and the connections available:
The whole range benefits from a set of inserts and rings for customizing the colour-coding in each country. Equipped with IP67 connections to ensure water-proofing, the CA8435 is also compatible with all the existing Qualistar measuring accessories.
Connections:
The Qualistar models are ideal for applications on all types of electrical networks, from the simplest to the most complex:
Chauvin Arnoux Power and Energy quality Analysers CA8331/CA8333/CA8336/CA8436 | ||||
Technical Specification | CA8331 | CA8333 | CA8336 | CA8436 |
Number of Channels | 3U / 4I | 4U / 4I | ||
Number of Inputs | 4V / 3I | 5V 4I | ||
Voltage (TRMS AC+DC) | 2V to 1,000V | |||
Voltage Ratio | Up to 500kV | |||
Current (TRMS AC+DC) MN Clamps | MN93: 500 mA to 200 Aac; MN93A: 0.005 Aac to 100 Aac | |||
C193 Clamp | 1 A to 1,000 Aac | |||
AmpFlex® or MiniFlex® clamps | 100 mA to 10,000 Aac | |||
PAC93 Clamp | 1 A to 1,300 Aac/dc | |||
E3N Clamp | 50 mA to 100 Aac/dc | |||
J93 | 50 A to 3,500 Aac / 5,000 Adc | |||
Current Ratio | up to 60 kA | |||
Frequency | 40 Hz to 69 Hz | |||
Power Values | W, VA, var, VAD, PF, DPF, cos φ, tan φ | |||
Energy Values | Wh, varh, VAh, VADh | |||
Harmonics | Yes | |||
THD | yes, orders 0 to 50, phase | |||
Expert Mode | - | Yes | ||
Transients | - | 50 | 210 | |
Flicker Pst | Yes | |||
Plt | - | - | Yes | |
Inrush Mode | - | Yes on 4 periods | Yes> 10 minutes | |
Unbalance yes | Yes | |||
Recording Min/Max | Yes | |||
of a selection of parameters at the Max sampling rate. | 4 hours to 2 weeks | Few days to several weeks | 2 weeks to several years | |
Alarms | - | 4,000 of 10 different types | 10,000 of 40 different types | |
Peak | Yes | |||
Vectorial representation | Automatic | |||
Display | Colour ¼ VGA TFT screen, 320 x 240, diagonal 148 mm | |||
Capture of screens and curves | 12 | 50 | ||
Electrical safety | IEC 61010 1,000 V CAT III / 600 V CAT IV | |||
Protection | IP53 / IK08 | IP67 | ||
Languages | More than 27 | |||
Communication interface | USB | |||
Battery life | Up to 13 hours | |||
Power supply | 9.6 V NiMH rechargeable battery or external mains charger | |||
Dimensions | 240 x 180 x 55mm | 270x250x180mm | ||
Weight | 1.9Kg | 3.7Kg |
Reeling Box P01102149
Magnetised Voltage Probes P01103058Z
ESSAILEC connexion kit Adapter P01102131
CA833* Kit carry case, no22 P01298056
CA833* Instrument carry case, no21 P01298055
CA833* Lead carry case, no6 P01298051
PA30W, Mains power supply P01102057
Chauvin Arnoux Power and Energy quality Analysers CA8331/CA8333/CA8336/CA8436 | ||||
Technical Specification | CA8331 | CA8333 | CA8336 | CA8436 |
Number of Channels | 3U / 4I | 4U / 4I | ||
Number of Inputs | 4V / 3I | 5V 4I | ||
Voltage (TRMS AC+DC) | 2V to 1,000V | |||
Voltage Ratio | Up to 500kV | |||
Current (TRMS AC+DC) MN Clamps | MN93: 500 mA to 200 Aac; MN93A: 0.005 Aac to 100 Aac | |||
C193 Clamp | 1 A to 1,000 Aac | |||
AmpFlex® or MiniFlex® clamps | 100 mA to 10,000 Aac | |||
PAC93 Clamp | 1 A to 1,300 Aac/dc | |||
E3N Clamp | 50 mA to 100 Aac/dc | |||
J93 | 50 A to 3,500 Aac / 5,000 Adc | |||
Current Ratio | up to 60 kA | |||
Frequency | 40 Hz to 69 Hz | |||
Power Values | W, VA, var, VAD, PF, DPF, cos φ, tan φ | |||
Energy Values | Wh, varh, VAh, VADh | |||
Harmonics | Yes | |||
THD | yes, orders 0 to 50, phase | |||
Expert Mode | - | Yes | ||
Transients | - | 50 | 210 | |
Flicker Pst | Yes | |||
Plt | - | - | Yes | |
Inrush Mode | - | Yes on 4 periods | Yes> 10 minutes | |
Unbalance yes | Yes | |||
Recording Min/Max | Yes | |||
of a selection of parameters at the Max sampling rate. | 4 hours to 2 weeks | Few days to several weeks | 2 weeks to several years | |
Alarms | - | 4,000 of 10 different types | 10,000 of 40 different types | |
Peak | Yes | |||
Vectorial representation | Automatic | |||
Display | Colour ¼ VGA TFT screen, 320 x 240, diagonal 148 mm | |||
Capture of screens and curves | 12 | 50 | ||
Electrical safety | IEC 61010 1,000 V CAT III / 600 V CAT IV | |||
Protection | IP53 / IK08 | IP67 | ||
Languages | More than 27 | |||
Communication interface | USB | |||
Battery life | Up to 13 hours | |||
Power supply | 9.6 V NiMH rechargeable battery or external mains charger | |||
Dimensions | 240 x 180 x 55mm | 270x250x180mm | ||
Weight | 1.9Kg | 3.7Kg |
UK Mainland | Order by 2pm for Next Day Delivery* |
---|---|
Under £25.00 | £4.50 |
Over £25.00 | FREE |
UK Highlands & Islands | Order by 2pm for Next Day Delivery* |
---|---|
Under £80.00 | £15.00 |
Over £80.00 | FREE |