Kewtech Kew-mate 2001A Digital Multimeter With AC/DC Clamp Sensor

Product Code: KEW2001A

Price
£112.00 ex. VAT £134.40 inc. VAT

In Stock


Add To Favourites
Detailed Description

Key Features:

  • Capable of measuring AC and DC currents up to 100A with OPEN CLAMP SENSOR.
  • 3400 counts with bar graph display.
  • Pocket size and heavy-duty design.
  • Increased cable strength with new rubber protection
  • Test probe can be fixed to the holster.
  • Can measure AC/DC current and voltage.
  • With test lead cap to protect from short circuit accidents.
  • The open jaws are thin, and perfect for clamping wires even in tight spaces.

*Important Calibration Information:
This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘traceable calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.
Where calibration of an instrument is possible, we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a full traceable calibration certificate produced in our laboratory and applied with your details as required

 

A unique multi-functional device featuring thin jaws, perfect to clamp wires even in tight spaces where a normal clamp meter is too big or wires are too short.
Has a maximum resolution of 0.1A AC/DC.

Applications:

  • Everyday multimeters for technicians, the Kewmates are designed for electrical and electronic testing in field service and all applications where extra features, such as AC/DC current measurements up to 60/100/120A, simplify working.
  • Ideal for electrical and electronic troubleshooting in residential, commercial and industrial installations.
  • Thanks to the open clamp sensor, Kewmates are perfect for reading currents in tight spaces where a normal clamp meter would be unsafe or too big to use such as sub-distribution boards, consumer units, final circuits, connection boxes, control panels or simply where the wires are too short.
  • Optimized for measuring the output of a solar panel in photovoltaic installations.
  • DC current measurements permit electrical testing and servicing of cars, electric forklifts, small electric cars or trolleys for cleaning, DC motor adjustable speed controllers, golf cars and trolleys, small electric cars and chairlifts for the disabled, work platforms, UPS's, electric scooters and bikes, etc.

Application Examples:

Product Comparison Chart:

The Kew-mate comes in three variations, choose the correct model for you from the table below.

  2000A 2001A 2012RA
DC V 340.0mV/3.400/34.00/340.0/600V (Input impedance: 10MΩ)
±1.5%rdg±4dgt
600.0mV/6.000/60.00/600.0V (Input impedance: approx. 10MΩ)
±1.0%rdg±3dgt
AC V 3.400/34.00/340.0/600V (Input impedance: 10MΩ)
±1.5%rdg±5dg (50 - 400Hz)
6.000/60.00/600.0V (Input impedance: approx. 10MΩ)
±1.5%rdg±5dgt (45 - 400Hz)
DC A 60.0A
±2.0%rdg±5dgt
100.0A
±2.0%rdg±5dgt
60.00/120.0A
±2.0%rdg±8dgt (60A)
±2.0%rdg±5dgt (120A)
AC A 60.0A
±2.0%rdg±5dg (50/60Hz)
100.0A
±2.0%rdg±5dg (50/60Hz)
60.00/120.0A
±2.0%rdg±5dgt (45 - 65Hz)
Ω 340.0Ω/3.400/34.00/340.0kΩ/3.400/34.00MΩ
±1.0%rdg±3dg (340Ω/3.4/34/340kΩ)
±5.0%rdg±5dg (3.4MΩ)
±15.0%rdg±5dg (34MΩ)
600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
±1.0%rdg±5dgt (600Ω/6/60/600kΩ)
±2.0%rdg±5dgt (6MΩ)
±3.0%rdg±5dgt (60MΩ)
Continuity buzzer Buzzer sounds below 30±10Ω Buzzer sounds below 35±25Ω
Diode test 2.000V ±3.0%rdg±5dgt, Open-loop voltage: approx. 2.7V
Capacitance 400.0nF/4.000/40.00μF
±2.5%rdg±10dgt
Frequency (AC A)
(AC V)
3.400/10.00kHz
±0.1%rdg±1dgt 3.400/34.00/300.0kHz
±0.1%rdg±1dgt
  (AC A)
(AC V)
99.99/400.0Hz
±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (400Hz) 99.99/999.9Hz/9.999/99.99/300.0kHz
±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (1000Hz/10/100/300kHz)
Input sensitivity Current: more than 15A
Voltage: more than 30V
Current: more than 25A
Voltage: more than 30V
Current: more than 6A
Voltage: more than 6V [-10kHz]/more than 20V [10k - 300kHz])
Conductor size ø6 mm max. ø10 mm max. ø12 mm max.
Applicable standards IEC 61010-1 CATⅢ 300V, CATⅡ 600V Pollution degree 2, IEC 61010-2-032, IEC 61010-031, IEC 61326-1, EN 50581(RoHS)
Power source R03(AAA)(1.5V) × 2
* Continuous measuring time: approx. 45hours (Auto power save: approx. 10 minutes)
R03(AAA)(1.5V) × 2
* Continuous measuring time:
DC V: approx. 150 hours, AC A: approx. 25 hours (Auto power save: approx. 15 minutes)
Dimensions 128(L) × 87(W) × 24(D) mm 128(L) × 92(W) × 27(D) mm
Weight 210g approx. (including batteries) 220g approx. (including batteries)
Accessories R03(AAA) × 2, Instruction manual
Optional 9107 (Carrying case [Soft])

Kewtech 2001A Technical Specification
DC V 340.0mV/3.400/34.00/340.0/600V (Input Impedance: 10MΩ)
±1.5%rdg±4dgt
AC V 3.400/34.00/340.0/600V (Input Impedance: 10MΩ)
±1.5%rdg±5dgt [50 - 400Hz]
DC A 100.0A ±2%rdg±5dgt
AC A 100.0A ±2%rdg±5dgt (50/60Hz)
Ω 340.0Ω/3.400/34.00/340.0kΩ/3.400/34.00MΩ
±1%rdg±3dgt (0 - 340kΩ)
±5%rdg±5dgt (3.4MΩ)
±15%rdg±5dgt (34MΩ)
Continuity buzzer Buzzer sounds below 30±10Ω
(Continuity buzzer works on 340Ω range only)
Frequency (AC A) 3.400/10.00kHz ±0.1%rdg±1dgt
(AC V) 3.400/34.00/300.0kHz ±0.1%rdg±1dgt
(Input sensitivity Current: more than 25A, Voltage: more than 30V)
Conductor size Ø10mm max.
Applicable standards IEC 61010-1 CAT III 300V, CAT II 600V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1, EN 50581(RoHS)
Power source R03 (AAA)(1.5V) × 2
* Continuous measuring time: approx. 45 hours
(Auto power save: approx. 10 minutes)
Dimensions 128(L) × 92(W) × 27(D)mm
Weight 220g approx. (including batteries)
Included Accessories R03 (AAA) × 2, Instruction Manual
Optional Accessories 9107 (Carrying case [Soft])