Fluke 116 Multimeter 62 Max+ IR Thermometer HVAC Kit

Product Code: FLU116-62MX+

Price
£318.75 ex. VAT £382.50 inc. VAT

In Stock


Add To Favourites
Detailed Description

Kit Includes:

  • Fluke 116 True RMS Digital Multimeter
  • Fluke 62 MAX+ IR Thermometer
  • Velcro pipe wrap thermocouple
  • 80AK K Type Thermocouple Adaptor
  • TPAK1 magnetic wall-hanging kit
  • 80PK-1 bead probe
  • TL175 TwistGuard Test Leads
  • C115 soft carry case

*Important Calibration Information:
This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘traceable calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.
Where calibration of an instrument is possible, we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a full traceable calibration certificate produced in our laboratory and applied with your details as required.

For Every HVAC professional

For the complete solution to HVAC troubleshooting the extra value-packed HVAC Technician’s Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.

Fluke116 Digital Multimeter. Designed by Electricians. Engineered by Fluke.

  • Fluke 116 HVAC Multimeter with Temperature and Microamps.
  • TL175 Hard Point Test Lead Set.
  • TPak ToolPak Magnetic Meter Hanging Strap.
  • Flexible Cuff Pipe Clamp Thermocouple.
  • 80BK Integrated Temperature Probe.
  • 80AK-A Thermocouple Adapter.
  • C115 Deluxe Soft Carrying Case with Shoulder Strap.

Fluke 62 MAX+. Small in size. Big on toughness.

  • Dust and water-resistant: IP54 rated.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Distance to spot: 12:1.
  • Dual lasers: Identifies area to be measured.
  • Large, backlit display: Makes data easier to read, even in dark areas.

 

Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating Temperature -10 °C to + 50 °C
Storage Temperature -40 °C to + 60 °C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life 400 hours typical, without backlight

 

Accuracy Specifications
DC millivolts Range 600.0 mV
Resolution 0.1 mV
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/Resolution 6.000 V / 0.001 V
Range/Resolution 60.00 V / 0.01 V
Range/Resolution 600.00 V / 0.1 V
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Auto volts Range 600.0 V
Resolution 0.1 V
Accuracy 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms Range 600.0 mV
Resolution 0.1 mV
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms Range/Resolution 6.000 V / 0.001 V
Range/Resolution 60.00 V / 0.01 V
Range/Resolution 600.0 V / 0.1 V
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity Range 600 Ω
Resolution 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms Range/Resolution 600.0 Ω / 0.1 Ω
Range/Resolution 6.000 kΩ / 0.001 kΩ
Range/Resolution 60.00 kΩ / 0.01 kΩ
Range/Resolution 600.0 kΩ / 0.1 kΩ
Range/Resolution 6.000 MΩ / 0.001 MΩ
Accuracy 0.9 % + 1
Range/Resolution 40.00 MΩ / 0.01 MΩ
Accuracy 1.5 % + 2
Diode Test Range/Resolution  2.000 V / 0.001 V
Accuracy  0.9% + 2
Capacitance Range/Resolution 1000 nF / 1 nF
Range/Resolution 10.00 μF / 0.01 μF
Range/Resolution 100.0 μF / 0.1 μF
Range/Resolution 9999 μF / 1 μF
Range/Resolution 100 μF to 1000 μF
Accuracy 1.9% + 2
Range/Resolution > 1000 μF
Accuracy 5% + 20%
LoZ capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
Temperature2 (Type-K thermocouple) Range/Resolution -40 °C to 400 °C / 0.1 °C
Accuracy 1% + 102
Range/Resolution -40 °F to 752 °F / 0.2 °F
Accuracy 1% + 182
AC μamps true-rms (45 Hz to 500 Hz) Range/Resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
DC μamps Range/Resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
Hz (V or A input)2 Range/Resolution 99.99 Hz / 0.01 Hz
Range/Resolution 999.99 Hz / 0.1 Hz
Range/Resolution 9.999 Hz / 0.001 Hz
Range/Resolution 50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

 

Mechanical & General Specifications
Size 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight 550 g
Warranty 3 years

 

Fluke 62 MAX+ Infrared Thermometer

 

Specifications

Temperature Range

-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%) Fluke 62+ MAX <300 ms (95% of reading)
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00

Optical Resolution

12:1 (calculated at 90% energy)
Display Resolution 0.1 °C (0.2 °F)
Repeatability of Readings ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power AA battery
Battery Life 8 hours with laser and backlight on
Physical Specifications Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II
UK Mainland Order by 2pm for Next Day Delivery*
Under £25.00 £4.50
Over £25.00 FREE

UK Highlands & Islands Order by 2pm for Next Day Delivery*
Under £80.00 £15.00
Over £80.00 FREE

Recently Viewed