Key Features:

  • AC/DC voltage range: 600V
  • AC/DC current range: 10A
  • Resistance range: 20MΩ
  • Diode test
  • Continuity test
  • LCD digital screen
CALIBRATION ISS DMM

The Martindale MM39 multimeter is autoranging and features a large rotary knob for easy selection of the required test, even when wearing gloves.

There are two additional buttons, one to lock the range and the other to hold the result on the display. The multimeter functions include DC Volts, AC Volts, AC Amps, Ohms, Continuity with Audible Indication and Diode Test.

Each MM39 multimeter is supplied with standard test leads, batteries, protective rubber holster and instruction manual.

MM39 Multimeter Comes Supplied With:

  • TL16 Test Leads
  • 2 x 1.5V Batteries
  • Instruction Manual
Martindale MM39 Auto Ranging Multimeter
Display 3.5 inch digit liquid crystal display (LCD) with max reading of 1999
Polarity Automatic, positive implied, negative polarity indication
Overrange (OL) or (-OL) is displayed
Zero Automatic
Low battery Symbol displayed when below certain level
Measurement Rate 2 times per second, nominal
Auto Power Off Approx. 10 mins
Operating Environment 0 to 50°C at <70% relative humidity
Storage Temperature -20 to 60°C at <80% relative humidity
Accuracy Stated accuracy at 23°C ±5°C, <75% relative humidity
Temperature Coefficient 0.1 x (specified accuracy) per °C (0 to 18°C, 28-50°C)
Altitude 6561.7 feet (2000m)
Power 1.5V batteries x 2, RO3/Size AAA
Battery Life 200 hours typical with carbon-zinc
Dimensions 145mm (H) x 70mm (W) x 34mm (D)
Weight Approx 11.1oz (315g) including holster
DC Volts  
DC Voltage Range 200mV, 2V, 20V, 200V, 600V
DC Resolution 0.1mV
Accuracy ±(1.0% rdg + 2 dgts)
Input Impedance 200mV: >100MΩ: 2V: 10MΩ, 20V-600V: 9.1MΩ
Overload Protection 600VDC or AC RMS
AC Volts (50Hz-500Hz)  
Ranges 200mV, 2V, 20V, 200V, 600V
Resolution 0.1mV
Accuracy ±(2.0% rdg + 5dgts) 50Hz-100Hz on 200mV range, ±(2.0% rdg + 5 dgts)
Input Impedance 200mV: >100MΩ: 2V: 10MΩ, 20V-600V: 9.1MΩ
Overload Protection 600V DC or AC rms
Current  
Ranges 10A
Resolution 0.01A
DC Accuracy ±)3.0% rdg + 3 dgts)
AC Accuracy (50Hz-500Hz) ± (3.5% rdg + 5 dgts)
Voltage Burden 0.2V
Input Protection 10A/500V fast blow ceramic fuse
Resistance  
Ranges 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ
Resolution 0.1Ω
Accuracy ±(1.5% rdg + 4 dgts) on 200Ω to 200kΩ ranges
±(2.5% rdg +4 dgts) on 2MΩ range
±(5.0% rdg + 5 dgts) on 20MΩ range
Open Circuit Volts -0.45Vdc (-1.2Vdc on 200Ω range)
Overload Protection 500V DC or AC rms
Diode Test  
Test Current 1.0mA (approximate)
Accuracy ±(3.0% rdg + 3 dgts)
Resolution 10mV
Audible Indication <0.25V
Open Circuit Volts 3.0Vdc typical
Overload Protection 500V DC or AC rms
Continuity  
Audible Indication Less than 25Ω
Response Time 500ms
Overload Protection 500V DC or AC rms