Solid performing entry-level tester from Fluke's flagship range
The 1662 puts more power in your hands by quickly and efficiently testing to all local regulations, protecting appliances that may be inadvertently connected to the system under test, and making it easy to share test results over your smartphone. Safety and performance are two of the most critical requirements for any electrical system. Good quality insulation, a properly working grounding system and active protection assure the safety of people, electrical systems and buildings, and protect them against electrocution, fire and other equipment damage.
The versatility of the Fluke Multifunction Tester
Insulation-continuity test: our installation tester does the job.
Fluke installation testers can be used to perform an insulation-continuity test, which is designed to diagnose and prevent the breakdown of the insulation in various parts of the electrical system such as wires, transformers and motors. The quality of insulation is critical to assure proper, uninterrupted and safe functioning of electrical circuits.
Checking RCD devices with a Fluke multifunction tester.
Our versatile installation testers can also check the proper functioning of residual-current devices (RCDs). RCDs are designed to disconnect quickly to mitigate the harm caused from electric shock and to avoid current leaks that may lead to fire and other dangerous situations. Our installation testers assure that RCDs can properly perform this important task.
The perfect loop testing tool: a Fluke installation tester.
Loop testing is a quick, convenient, and highly specific method of evaluating an electrical circuit for its ability to engage protective devices (circuit breakers, fuses, RCDs). A ground loop determines the effectiveness of protective devices.
Resistance measurement of grounding systems.
The electrical installation testing abilities of the Fluke installation tester also include verification tests to ensure that a system's resistance is low enough to provide protection to people, equipment and structures. A properly functioning grounding system is a critical safety feature of an electrical system.
Measurement Functions:
- Voltage & frequency
- Wiring polarity checker, detects broken N wires
- Insulation resistance
- Continuity & resistance
- Measure motor windings with continuity test
- Loop & line resistance
- Prospective earth fault current (PEFC/IK)
- Prospective short-circuit current (PSC/IK)
- RCD switching time
- RCD tripping level (ramp test)
- Measures trip time & current for RCD type A & AC in one test
- RCD variable current
- Automatic RCD test sequence
- Phase sequence indicator
Other features:
- On/Off switchable auto-start for RCD & Looptest
- Self-test
- Illuminated display
- Time and date (when used with optional FlukeView software)
Fluke 166x Series Comparison Guide
Which is the right model for me?
The new Fluke 1660 Series Multifunction Installation Testers are the only installation testers that help prevent damage to connected appliances, while allowing users to wirelessly e-mail results from the field. Auto Test does all required installation tests in one sequence, ensuring compliance with local installation regulations.
Old Model
|
New Model
|
Features Changes & What's New
|
1651
|
1662
|
- RCD tripping current level ramp test
- RCD auto test and ramp test
- Pulsating dc sensitive RCD tests (G & S-type)
- Remote probe
- On/Off switchable auto-start for RCD and Looptest
- Heavy duty, single input line cord
- Computer interface
|
1652
|
1662
|
- On/Off switchable auto-start for RCD and Looptest
- Heavy duty, single input line cord
- Computer interface
|
1653
|
1663
|
- Continuity at L-N, N-PE inputs
- On/Off switchable auto-start for RCD and looptest
- Z max memory
- Heavy duty, single input line cord
|
1654
|
1664 FC
|
- Insulation-PreTestâ⢠safety function
- Insulation at L-N, N-PE inputs
- Automatic test sequence
- Continuity at L-N, N-PE inputs
- Fluke Connectî compatibility
- ShareLiveâ⢠Calling
- FlukeCloudâ⢠Storage
- On/Off switchable auto-start for RCD and looptest
- Z max memory
- Heavy duty, single input line cord
|
AC voltage measurement |
Range |
500 V |
Resolution |
0.1 V |
Accuracy 45 Hz – 66 Hz |
0.8% + 3 |
Input impedance |
360 kΩ |
Overload protection |
660 V rms |
Continuity testing (RLO) |
Range (autoranging) |
20 Ω / 200 Ω / 2000 Ω |
Resolution |
0.01 Ω / 0.1 Ω / 1 Ω |
Open Circuit Voltage |
>4 V |
Insulation resistance measurement (RISO) |
Test voltages |
100-250-500-1000 V |
Accuracy of tTest voltage (at rated test current) |
+10%, -0% |
Test voltage |
50 V 100 V 250 V 500 V 1000 V |
Insulation resistance range |
20 MΩ /50 MΩ 20 MΩ / 100 MΩ 20 MΩ / 200 MΩ 20 MΩ / 200 MΩ / 500 MΩ 20 MΩ / 200 MΩ / 1000 MΩ |
Resolution |
0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ |
Test current |
1 mA @ 50 kΩ 1 mA @ 100 kΩ 1 mA @ 250 kΩ 1 mA @ 500 kΩ 1 mA @ 1 MΩ |
Loop and line impedance (ZI) |
Range |
10 Ω / 0.001 Ω / High current mΩ mode |
Resolution |
0.01 Ω / 0.1 Ω / 1 Ω |
Prospective earth fault current, PSC test |
Range |
1000 A / 10 kA (50 kA) |
Resolution |
1 A / 0.1 kA |
Computation |
Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively. |
RCD testing, RCD types tested |
RCD Type |
AC¹ G²,S³ |
Model 1662 |
A4, AC¹, G²,S³ |
Notes |
¹Responds to AC ²General, no delay ³Time delay 4Responds to pulsed signal 5Responds to smooth DC signal |
Tripping speed test (ΔT) |
Current settings¹ |
10-30-100-300-500-1000 mA – VAR 10-30-100 mA |
Multiplier |
x ½, x 1 x 5 |
Measurement range |
RCD Type G |
310 ms 50 ms |
RCD Type S |
510 ms 160 ms |
Notes |
¹1000 mA type AC only 700 mA maximum type A in VAR mode VAR mode not available for type B. |
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN) |
Current range |
30% to 110% of RCD rated current¹ |
Step size |
10% of IΔN² |
Dwell time |
Type G |
300 ms/step |
Type S |
500 ms/step |
Measurement accuracy |
±5% |
Specified trip current ranges (EN 61008-1) |
50% to 100% for Type AC 35% to 140% for Type A (>10 mA) 35% to 200% for Type A (≤10 mA) 50% to 200% for Type B ²5% for Type B |
Notes |
¹30% to 150% for Type A IΔN > 10 mA 30% to 210% for Type A IΔN = 10 mA 20% to 210% for Type B |
Phase Sequence Indication |
Icon |
Phase Sequence indicator is active. |
General Specifications |
Size (L x W x H) |
10 x 25 x 12.5 cm |
Weight (incl. batteries) |
1.3 Kg |
Battery size, quantity |
Type AA, 6 ea. |
Sealing |
IP-40 |
Safety |
Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s 82.02.01 2000
and CAN/CSA c22.2 No. 1010 2nd edition
|
Overvoltage |
CAT III / 500V; CAT IV 300V |
Performance |
EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition |
|