Product Code: CHACA6117
In Stock
*optional accessories are required for some tests
*Important Calibration Information:
This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘traceable calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.
Where calibration of an instrument is possible we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a full traceable calibration certificate produced in our laboratory and applied with your details as required.
The CA 6117 is an ALL-IN-ONE instrument for testing electrical installations in compliance with national and international standards (IEC 60364-6, NF C 15-100, VDE 100, FD C 16-600, etc) -AC, A, F, B, B+, EV and RCD testing.
It combines design, ergonomics, simplicity, performance, rapidity and accuracy.
Suitable for all neutral systems (TT, TN, IT), it is ideal for all sectors: industry, tertiary and residential.
Boasting an unrivalled set of features the CA6117 is a multifunction tester capable of live 1P live-circuit earth measurement, 3P earth measurement and 1P power analysis. Please see the comprehensive documentation available in the resources tab above for more information or give us a call FREE on 0800 0224 060
|
![]() |
• 1x CA6117 multifunction tester with heavy-duty nylon carrying bag
• 1x type-2 mains power pack /charger
• 1x Li-Ion battery pack
• 1x USB A/B cable, 1.80 m, with ferrite
• 1x three-point cable - 3 safety leads (red, blue and green)
• 3x test probes, Ø 4 mm (red, blue and green)
• 3x crocodile clips (red, blue and green)
• 2x elbowed-straight safety leads 3 m (red and black)
• 1x three-point Euro mains cable
• 1x 2P EURO mains cable
• 1x remote-control probe
• 1x wrist strap
• 1x 4-point hands-free strap
• ICT data export software on CD-ROM (Dataview FULL version)
• 6x operating manuals on CD (one per language)
• 1x safety datasheet
The rugged, compact CA 6117 is specially designed for quick and effective familiarization. On its large LCD graphical colour display with backlighting, users can view all the crucial results at a glance.
A rotary switch on the instrument’s front panel gives direct access to all the functions. A large number of visual symbols and audio signals help with quick interpretation of the results in accordance with the standards. The on-line contextual help menus can guide the user step by step, if needed. The storage capacity can save up to 1,000 tests. The CA 6117 also has a USB output for data transfer.
Guaranteed Safety:The testers are equipped with a clear, detailed contextual help function. |
![]() |
The high-performance CA 6117 offers excellent measurement stability, even in disturbed industrial environments. All the measurements needed to test an electrical installation are available: continuity, resistance, insulation, earth and selective earth, loop impedances, type A and AC RCDs. The CA 6117 can also be used to measure voltage, frequency, current via a clamp, active power, harmonics and phase rotation.
The CA 6117 is also fitted with type-B RCD testing, built-in fuse table and voltage-drop feature.
Designed and manufactured in France, the CA 6117 was developed in compliance with eco-design procedures.
The dedicated Chauvin Arnoux 3P earth kit can be purchased from the drop-down selection above for a specially discounted rate when you buy the CA6117 Multifunction tester.
Correct earthing guarantees user safety and also protects property and installations in the event of lightning or fault currents. It must always be linked to a cut-off device.
There are many different methods for earth measurements and choice of the right one depends on the type of neutral system, the type of installation (domestic, industrial, urban, rural, etc.) and the possibility of cutting off the power supply.
3-pole earth measurement using 2 auxiliary stakes (also known as the 62 % method) is the earth measurement of reference which yields a precise resistance value for the earth electrode. As it is performed with the power off, this is the only earth measurement possible on an installation which has not yet been hooked up to the electrical power distribution network or which is no longer connected to it.
Once the cables have been connected, implementation is particularly simple. All you have to do is set the rotary switch to RE 3P, press test and read off the result. Users can choose the test mode: quick or expert. In expert mode, the resistance values of the auxiliary stakes RS and RH are also measured.
The tester can measure harmonics up to the 50th order and displays the graph.
The THD-F, THD-R and voltage values are displayed simultaneously, along with the name of the line selected and its amplitude.
In this mode, users can choose between FFT analysis of the voltage or the current and display with a linear or logarithmic scale.
On a three-phase network, this measurement can be used to check the phase sequence on the network.
The tester checks the frequency of the 3 signals and then compares them to detect their sequence (negative or positive).
The dedicated Chauvin Arnoux C177A power analyser clamp can be purchased from the drop-down selection above for a specially discounted rate when you buy the CA6117 Multifunction tester.
In the modern workplace electricians must deal with an array of complex array of work and equipment, by having high spec equipment , such as the CA6117 multi-function tester, they can be prepared for every eventuality encountered. Many MFTs prove sufficient for basic safety testing, but when it comes to fault finding, commissioning and diagnostics, advanced MFTs like the CA6117 come into their own by providing everything the modern electrician needs in one product.
The CA6117 can display voltage, and, by using the optional current clamp, current waveforms while also displaying both peak (max) and RMS values. This proves useful in identifying any waveform distortion, possibly from harmonics or other sources. Power can also be displayed with direction indication for imported or exported power, ideal where microgeneration such as PV systems are present. Power Factor can be measured and seen on the graphical display. These features are essential for those working in modern electrical systems with capacitive, inductive and non-linear loads present. The ability to see these values in real-time assists in quickly diagnosing issues within the installation or supply. They are also essential when configuring or testing equipment such as power factor correction capacitor banks.
Using the voltage input and optional current clamp, the CA6117 has the ability to accurately measure and display Voltage and Current Harmonics up to the 50th harmonic order, performance typically only seen on dedicated power quality analysers or loggers. All modern electrical installations contain non-linear loads which generate harmonics.
These harmonics can cause many issues within installations, such as the overheating and premature failure of equipment. The only way to identify the underlying cause of these issues is by using a meter such as the CA6117 or an expensive power quality analyser or logger. The CA6117 has the ability to display Total Harmonic Distortion (THD), a simple measure of the amount of harmonics present. It can also show each of the 50 individual harmonics in graphical or numerical form. This powerful feature allows the electrician to identify specific harmonic issues and also check the effectiveness of harmonic mitigation measures, such as active harmonic filters.
A stand-out feature of the CA 6117 is its ultra-accurate Earth Fault Loop Impedance (Zs) measurement capability. Unlike most MFTs on the market, the CA 6117 is able to measure Zs to three decimal places and test lead resistance can also be nulled in Zs mode. In heavy duty installations or where working on installations close to the supply transformer, Zs values can be very low. To measure such low values, which are beyony the meaningful range of most MFTs, electricians may have to buy a expensive specialist stand-alone loop tester, but not with the CA 6117 which can measure these values using its normal high current Zs range.
The measurements made with the CA 6117 can be processed by the DataView® multi-product expert processing software. DataView® automatically recognizes the instrument when it is connected to the PC and opens the corresponding menu. By means of a tree structure, it offers users direct access to the data recorded in the instrument, its configuration, etc.
It is equipped with multiple predefined report templates which comply with the standards' requirements.
Users can also create their own templates, as required.
Delivered as standard, the ICT software offers the following functions for quick, simplified analysis of the recorded measurements: recovery of the data, configuration of the instrument, customization of measurement campaigns with transfer into the instrument and generation of reports.
This specific software for the installation testers can be used for quick, simplified analysis of the measurements recorded by the CA 6117 tester. It is part of the standard delivery and offers the following functions:
• Data recovery
• Instrument parameter settings
• Customization of measurement sessions with transfer into the instrument
• Printing of first-level reports
The menu presents the tree structure of the data present in the product and measurement campaigns, clearly identified (customer, location, type of measurements, etc).
DataView®
(FREE Full-version for Microsoft Windows supplied with this purchase)
The measurements made can also be processed by the DataView® multi-product expert software.
DataView® automatically recognizes the instrument when it is connected to the PC and opens the corresponding menu.
This menu, displayed as a tree structure, gives users direct access to the data recorded in the instrument, its confi guration, etc.
DataView® contains multiple predefined report templates for quick printing in compliance with the applicable standards. Users can also create their own templates to meet their specific requirements.
The Earth Kit is used with earth and resistivity testers implementing the 3P loop method.
This Chauvin Arnoux earth and earth & resistivity kit is ideal for resistance measurement of normative earth rod on powered-down installations using 2 auxiliary rods (by 62% method).
It is offered also as an ideal accessory to the Chauvin Arnoux CA6117 high-performance multifunction tester.
Simple connections
The colours of the cables are identical to the colours of the connecting terminals of all of our instruments, so no mistakes are possible! The cable lengths are perfectly matched to the applications for which our kits are intended.
Easy to use
For a firm grip during installation, there are handles on the coils of cable. The handles can be removed to facilitate storage.
Universal
Our kits are compatible with all of our instruments, no matter which types of connectors they use, thanks to the 4 mm Ø. banana jack/fork plug adapters provided.
Compact
The carrying bags provided are designed to facilitate storage and transport of the accessories in separate
compartments.
Our earth kits are used to measure the resistance of existing earth probes by the 3P method (2 auxiliary
rods) E.g.: measurement of earth resistance RE by the “62 %” method.
Chauvin Arnoux CA 6117 Multifunction Tester Technical Specification | |||||||
CONTINUITY / RESISTANCE | |||||||
I rated / Range / Resolution | I > 200 mA / 39.99 Ω/ 0.01Ω / ± (1.5 % of measurement + 2 cts) 12 mA / 39.99 Ω & 399.9 Ω / 0.01 & 0.1 Ω /± (1.5 % of measurement + 5 cts) with beep |
||||||
Range / Resolution / Accuracy | 4 kΩ/ 1 Ω / ±(1.5 % of measurement + 5 cts) 40 kΩ - 400 kΩ/ 10 Ω - 100 Ω / ±(1.5 % of measurement + 2 cts) | ||||||
INSULATION | |||||||
Rated voltage | Utest: 50 /100 / 250 / 500 / 1,000 VDC | ||||||
Range / Resolution / Accuracy | 0.01 MΩ to 2 GΩ / 10 kΩ to 1 MΩ / ±(5 % of measurement + 3 cts) | ||||||
Short-circuit current | ≤ 3 mA | ||||||
EARTH | |||||||
3P EARTH Range / Resolution / Accuracy |
0.50 Ω to 40 Ω/ 0.01 Ω / ±(2 % of measurement + 10 cts) 40 Ω to 15 kΩ / 0.1 Ω to 1 Ω / ±(2 % of measurement + 2 cts) 15 kΩ to 40 kΩ / 10 Ω/ ±(10 % of measurement + 2 cts ) |
||||||
Others | Measurement of resistance of auxiliary stakes RH & RS (up to 40 kΩ) | ||||||
Ufk | Complies with SEV 3569 | ||||||
1P SELECTIVE EARTH Range / Resolution / Accuracy |
0.20 Ω to 39.99 Ω - 40 Ω to 399.9 Ω / 0.01 Ω – 0.1 Ω / ±(10 % of measurement + 10 cts) (ISel via clamp) | ||||||
LOOP IMPEDANCE (Zs (L-PE) and Zi (L-N or L-L)) – 1P LIVE EARTH | |||||||
LIVE EARTH Installation voltage / Freq. |
90 to 500 V / 15.8 to 17.5 Hz - 45 to 65 Hz | ||||||
High-current mode with TRIP Zs (L-PE) & Zi (L-N or L-L) Range / Resolution / Accuracy |
Max. test current: 7.5 A (0.050) 0.100 Ω to 0.5 Ω / 0.001 Ω/ ±(10 % of measurement + 20 cts) • 0.5 Ω to 3.999 Ω / 0.001 Ω/ ±(5 % of measurement + 20 cts) 3.999 to 39.99 Ω/ 0.01Ω / ±(5 % of measurement + 2 cts) • 39.99 Ω to 399.99 Ω / 0.1 Ω/ ±(5 % of measurement + 2 cts) |
||||||
NO TRIP mode (Zs (L-PE) only) | Test current: 6 mA – 9 mA – 12 mA (as required) 0.20 Ω to 0.99 Ω / 0.01 Ω / ±(15 % of measurement + 10 cts) 1.00 to 1.99 Ω / 0.01 Ω / ±(15 % of measurement + 3 cts) 2.00 to 39.99 Ω / 0.01 Ω / ±(10 % of measurement + 3 cts) 40.00 Ω to 399.9 Ω / 0.1 Ω / ±(5 % of measurement + 2 cts) 400 to 3999 Ω / 1 Ω / ±(5 % of measurement + 2 cts) |
||||||
Calculation of Ik short-circuit current (PFC (Zs), I Sc PSCC (Zi) |
Fault current and short-circuit current: 0.1 A to 20 kA | ||||||
Integrated fuse table | Yes | ||||||
Voltage drop ∆V%(Zi) | -40 % to +40 % | ||||||
Others | Measurement of the resistive and inductive components of the Zs and Zi impedances | ||||||
AC, A and F-type RCDs | |||||||
Installation voltage / Frequency | 90 V to 500 V / 15.8 Hz to 17.5 Hz and 45 Hz to 65 Hz | ||||||
I∆n | 6*/10/30/100/300/500/650/1,000 mA (90 V – 280 V) or 6*/10/30/100/300/500 mA (280-550 V) or variable Ramp and pulse test | ||||||
No-trip test | at ½ I∆n – Duration: 1,000 ms or 2,000 ms | ||||||
Ramp mode | 0.2 to 0.5 x I∆n (Uf ) / 0.3 x I∆n to 1.06 x I∆n in increments of 3.3 % x I∆n | ||||||
Trip time measurement: Range / Resolution / Accuracy |
0.2 to 0.5 x I∆n (Uf ) / 0.5 x I∆n / 2 x I∆n (selective) / 5 x I∆n Pulse: 0 to 500 ms / 0.1 and 1 ms / 2 ms, Ramp mode: 0 to 200 ms / 0.1 ms / 2 ms |
||||||
B, B+ and EV-type RCDs | |||||||
Installation voltage / Frequency | 90 V to 280 V / 15.8 Hz to 17.5 Hz and 45 Hz to 65 Hz | ||||||
Test in ramp mode: I∆n | 6/10/30/100/300/500 mA or variable 6-499 mA |
||||||
Test in ramp mode | 0.2 x I∆N to 2.2 x I∆n | ||||||
Test in pulse mode at 2 x I∆n: I∆n | 6/10/30/100/ 300 mA or variable ≤ 250 mA 2.2 x 2 x I∆N |
||||||
Test in pulse mode at 4 x I∆n: I∆n | 6/10/30/100 mA or variable ≤ 125 mA 2.4 x 4 x I∆N |
||||||
OTHER MEASUREMENTS | |||||||
Current by clamps C177/C177A | (0.5 mA**) 5 mA to 19.99 A (C177) / 20 mA to 199.9 A (C177A) 5.0 mA to 199.9 A (C177A) |
||||||
Current by clamp MN77 | (1 mA**) 5.0 mA to 19.99 A | ||||||
Voltage | 0 to 550 VAC/DC / DC and 15.8 to 500 Hz | ||||||
Frequency | 10 to 500 Hz | ||||||
Phase rotation | 20 to 500 VAC | ||||||
Active power | 0 to 110 kW single-phase - 0 to 330 kW three-phase Simultaneous display of voltage and current waveforms |
||||||
Harmonics | Voltage and current / up to 50th order / THD-F /THD-R | ||||||
GENERAL SPECIFICATIONS | |||||||
Display | Large 5.7” backlit graphic colour LCD screen, 320 x 240 points | ||||||
Storage/Communication | via USB for data transfer and report creation | ||||||
Power supply: rechargeable battery | NiMH 9.6 V rated 4 Ah Lithium-ion 10.8 V rated 5.8 Ah |
||||||
Battery life | up to 24 hours up to 30 hours |
||||||
Dimensions / weight | 280 x 190 x 128 mm / 2.2 kg | ||||||
Protection | IP 53 / IK04 | ||||||
EMC | IEC 61326-1 | ||||||
Electrical safety | IEC 61010 -1 – 600 V CAT III – 300 V CAT IV – IEC 61557 |
UK Mainland | Order by 2pm for Next Day Delivery* |
---|---|
Under £25.00 | £4.50 |
Over £25.00 | FREE |
UK Highlands & Islands | Order by 2pm for Next Day Delivery* |
---|---|
Under £80.00 | £15.00 |
Over £80.00 | FREE |
Price £1134.00 £945.00
Available In 3-7 Days
Price £587.94 £489.95
Available In 3-7 Days
Price £48.00 £40.00
Available In 3-7 Days