Product Code: KEW3128
In Stock
*Important Calibration Information:
This instrument comes complete with the manufacturer’s calibration certificate. Please be aware that these certificates are generic and may also be time lapsed. If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply.
The Kewtech KEW3128 is a microprocessor controlled 12kVDC insulation resistance tester capable of providing insulation resistance values of up to 35TΩ.
Crucially, the KEW3128 is able to discharge dangerous capacitive charges, consequent when subjecting large DC voltages across inductive loads for set periods of time; allowing for safe testing of cable lengths and other HV equipment. Ideal for simple compliance testing and leakage current tests, the KEW 3128 can also be used to conduct more in depth diagnostic checks such as: PI - polarisation index measurements DAR - dielectric absorption ratio DD - dielectric discharge SV - step voltage measurement Test measurements can be viewed in ‘live time’ when connected to a PC or laptop, or on the instrument itself which features a large, 320x240 resolution graphical screen.
The in-built graphical screen can be scrolled through and zoomed in on specific points through the whole recording period (up to 90 mins), allowing for instant onsite diagnosis. Moreover, a ‘print screen’ function is provided enabling the user to record a Bitmap (.bmp) image of the screen. The Kewtech KEW3128 12kV tester features an impressive memory, capable of storing 40,000 measurements. When using and ‘KEW Windows’ software package, test data can be downloaded should further test verification or reports be required off-site.
The KEW3128 12kV tester is dual powered and can be operated from a mains supply or from an in-built re-chargeable battery. The insulation tester is supplied and can be operated from within a hard carry case that offers IP68 ingress protection (when the lid is closed), along with test leads, software and USB cable, calibration certificate and user manual.
Kewtech KEW3128 High Voltage Insulation Tester | ||||||
---|---|---|---|---|---|---|
Insulation Resistance | ||||||
Rated Voltage | 500V | 1000V | 2500V | 5000V | 10,000V | 12,000V |
Max Measurement Value | 500GΩ | 1TΩ | 2.5TΩ | 5TΩ | 35TΩ | |
Accuracy | 0 - 50GΩ: ±5% rdg±3dgt (not guaranteed with setting of 250V or less) | 100GΩ to 1TΩ: ±20% rdg | 250GΩ to 1TΩ: ±20% rdg | 500GΩ to 5TΩ: ±20%rdg | 1T to 10TΩ: ±20% rdg | |
50G to 500GΩ: ±20%rdg (not guaranteed with setting of 250V or less) | 10T to 35TΩ: values displayed, but accuracy isn't guaranteed | |||||
Short Circuit Current | Max 5.0mA | |||||
Load Resistor to Output Rated Voltage | 0.5MΩ or more | 1MΩ or more | 2.5MΩ or more | 5MΩ or more | 20MΩ or more | 24MΩ or more |
Output Voltage | ||||||
Rated Voltage | 500V | 1000V | 2500V | 5000V | 10,000V | 12,000V |
Monitor Accuracy | ±10%±20V | |||||
Output Accuracy | 0 to +20% | 0 to +10% | 0 to +10% | 0 to +10% | -5 to +5% | -5 to +5% |
Selectable Range | 50 to 600V (in steps of 5V) | 610 to 1200V (in steps of 10V) | 1225 to 3000V (in steps of 25V) | 3050 to 6000V (in steps of 50V) | 6100 to 10,000V (in steps of 100V) | 10100 to 12000V (in steps of 100V) |
Voltage Measurement | ||||||
Measuring Range | DC voltage: ±30 to ±600V | |||||
AC voltage: 30 to 600V (50/60Hz) | ||||||
Accuracy | ±2% rdg ±3dgt | |||||
Current Measurement | ||||||
Measuring Range | 5.0nA to 2.40mA (depending on the insulation resistance) | |||||
Capacitance Measurement | ||||||
Measuring Range | 5.0nF to 50.0μF | |||||
5.0nF to 1.0μF (display range: 5.0nF to 50.0μF) | ||||||
Accuracy | ±5% rdg ±5dgt | |||||
General Specifications | ||||||
Withstand Voltage | AC8770V: between line terminal and enclosure/5 seconds (50/60Hz) | |||||
AC6880V: between the measuring terminal and enclosure / 5sec (50/60Hz) | ||||||
AC2330V: between the power connector and enclosure / 5sec (50/60Hz) | ||||||
Operating Temperature and Humidity Range | -10 to 50°C (RH: 85% or less - when operating with an external power supply, no condensation) | |||||
0 to 40°C (RH: 85% or less - when operating with battery, no condensation) | ||||||
Storage Temperature/Humidity | -20 to 60°C (RH: 75% or less - no condensation) | |||||
Applicable Standards | IEC 61010-1 CAT IV 600V | |||||
Pollution Degree 2 | ||||||
IEC 61010-031 | ||||||
IEC 61326 | ||||||
IEC 60529 (IP64) - with lid closed | ||||||
Power | Rechargeable lead storage battery (12V) Charging time: approx 8 hours AC Power Supply: 100 to 240V (50/60Hz) Continuous measuring time approx 4 hours with a load of 100MΩ at the insulation resistance 12,000V range |
|||||
Dimensions | 330 (L) x 410 (W) x 180mm (D) - instrument + hard case | |||||
Weight | 9kg approx (including battery) - instrument + hard case |