Time Electronics 5080 PAT Calibrator

Product Code: TIM5080

Price
£2999.00 ex. VAT £3598.80 inc. VAT

Available In 3-7 Days


Add To Favourites
Detailed Description

Key Features:

  • Calibrate PAT Testers
  • Calibrate VDE0701 testers
  • Battery powered
  • LCD display of voltage & current
  • Safety interlock feature
  • Earth bond currents up to 50A AC
  • Load test currents up to 13A AC

A precision calibrator designed to provide rapid high accuracy calibration of portable appliance testers and insulation/continuity testers. The 5080 PAT calibrator has functions for earth bond, insulation, leakage, touch leakage, and load test.  

Housed in a robust safety case the 5080 is easily portable and ideal for field calibration work. It is battery powered, which ensures isolation and prevents inaccuracies due to stray leakage. Features include safety interlock that prevents contact with earth bond studs during insulation and leakage tests, and an LCD display for voltage and current.

The 5080 is a dedicated solution for PAT testers and part of the electrical testing calibration range from Time Electronics. Other models include the 5030 electrical tester calibrator for RCD, loop, insulation, earth testers and multifunction installation testers. For insulation testers the 5069 InsCal is a portable instrument with resistance up to 100GOhm, and 10kV operation.

Earth Bond
Values / Accuracy 20mΩ, accuracy 5%
190mΩ, 210mΩ, 950mΩ, 1.050mΩ, 1.08Ω, 2Ω, 10Ω, 18Ω, accuracy 1%
Open circuit voltage measurement Range: 0 to 20V
Accuracy: 0.25% of full scale
High current AC measurement Range: 0 to 50A AC
Accuracy: 0.5% of reading +/- 0.2A
Low current AC measurement Range: 0 to 2A AC
Accuracy: 0.5% of reading +/- 2mA
Low current DC measurement Range: 0 to 2A DC
Accuracy: 1% of reading +/- 2mA
Insulation
Values / Accuracy 95kΩ, 105kΩ, 500kΩ, 950kΩ, 1.05MΩ, 5MΩ, 10MΩ, accuracy 0.1%
20MΩ, 50MΩ, 100MΩ, accuracy 1.0%
Open circuit voltage measurement Range: 0 to 1kV DC
Accuracy: 0.25% of full scale
Current measurement Range: 0 to 20mA DC. Accuracy: 0.25% of full scale
Leakage
Nominal Leakage Currents At 230V AC of 0.5, 1, 2, 5, 10, 15mA
Mains voltage measurement Range: 0 to 500V AC
Accuracy 0.25% of full scale
Leakage current measurement Range: 0 to 20mA AC
Accuracy 0.25% of full scale
Touch Leakage
Current 1.9mA AC 50 +/-5 Hz, into 2K2 maximum load resistance
Current measurement Range: 0 to 2mA AC. Accuracy: 0.25% of full scale
Load Test
Mains voltage measurement Range: 0 to 500V AC
Accuracy: 0.25% of full scale
Load current measurement Range: 0 to 13A AC
Accuracy: 0.5% of full scale

Power Internal battery 6V re-chargeable NiCad, >200 hrs between charges.
Dimensions W406 x H175 x D330mm
Weight 5.5kg
Supplied With 4mm terminal box adaptor, 110V adaptor, IEC connector (for external load), battery charger, and user manual.
Optional Extras Calibration certificates traceable NPL and UKAS