Product Code: CHACA6418
Available In 3-7 Days
*Important Calibration Information:
This instrument comes supplied with a ‘manufacturers calibration protocol’ please note this is NOT a traceable calibration certificate. A calibration protocol is a statement of values or tolerances within the desired range that the instrument was reading at the point of manufacture. A calibration protocol may not be an acceptable statement of accuracy according to industry accreditation bodies.
If you require a traceable calibration certificate accredited to your business, please select this option where applicable from the drop-down field below.
The CA6418 earth clamp from Chauvin Arnoux, delivered in a carrying case, can be used for quick testing of earth resistance.
With a clamping capacity that allows measurements on 30 x 40mm or 20 x 55mm rectangular bars and cables 32mm in diameter. The CA6418 clamp simultaneously displays the earth resistance and leakage current.
Ergonomically designed, with features such as an OLED display, ensures 180-degree visibility in all lighting conditions. An automatic "pre-Hold" mode when the clamp is opened and automatic compensation of the jaw gap when powering up ensure optimized processing of the measurements provided by the CA6418 clamp.
With a large internal memory- measurements can be stored with a time and date stamp, thanks to the real-time clock.
Chauvin Arnoux CA 6418 Clampmeter Technical Specifications | ||||||||
Loop Ohmmeter | ||||||||
Measurement Ranges | 0.010 to 0.099 Ω | 0.10 to 0.99 Ω | 1 to 49.9 Ω | 50 to 149 Ω | 150 to 245 Ω | 250 to 440 Ω | 450 to 640 Ω | 650 to 1,200 Ω |
Resolution | 1 mΩ | 10 mΩ | 100 mΩ | 1 Ω | 5 Ω | 10 Ω | 10 Ω | 50 Ω |
Accuracy | ± (1.5 %R* + 0.01 Ω) | ± (1.5 %R + 2 r) | ± (1.5 %R + 2 r) | ± (2.5 %R + 2 r) | ± (5 %R + 2 r) | ± (10 %R + 2 r) | ± (15 %R + 2 r) | ± (20 %R + 2 r) |
No-load Voltage | ≤ 4.5 mV to 2,083 Hz | |||||||
Ammeter | ||||||||
Measurement Ranges | 0.5 to 9.995 mA | 10.00 to 99.90 mA | 100.0 to 299.0 mA | 0.300 to 2.990 A | 3.00 to 20.00 A | |||
Resolution | 50 µA | 100 µA | 1 mA | 10 mA | 100 mA | |||
Accuracy | ± (2 %R + 200 µA) | ± (2 %R + r) | ± (2 %R + r) | ± (2 %R + r) | ± (2 %R + r) | |||
Setup | ||||||||
Alarms | Configurable for Z and I | |||||||
Buzzer | Active | |||||||
HOLD | Manual or automatic PRE-Hold | |||||||
Automatic power-off | Active / Inactive | |||||||
General Specifications | ||||||||
Loop Ohmmeter | ||||||||
Display | OLED 152 segments – Active area 48 x 39 mm | |||||||
Storage | 300 time/date-stamped measurements | |||||||
Power Supply | 4 x 1.5 V LR6 AA alkaline batteries or 4 NiMH batteries | |||||||
Battery Life | 2,400 x 30 s measurements | |||||||
Calibration | Automatic at start-up | |||||||
IEC61010 | 100 V CAT IV , 150 V CAT III | |||||||
Ingress Protection | IP 40 | |||||||
Dimensions | 300 x 106 x 56 mm | |||||||
Weight | 1.2 kg approx. including batteries |
UK Mainland | Order by 2pm for Next Day Delivery* |
---|---|
Under £25.00 | £4.50 |
Over £25.00 | FREE |
UK Highlands & Islands | Order by 2pm for Next Day Delivery* |
---|---|
Under £80.00 | £15.00 |
Over £80.00 | FREE |