Key Features:

  • Three ranges: 20A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 178 mm
  • CAT III 600V safety rating

The i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas. 

  
Electrical specifications
Current ranges
   20 A
   200 A
   2000 A
   AC rms
Output sensitivity (AC-coupled)
   100 mV
   10 mV
   1 mV
   1 mV per A
Load impedance
   100 kΩ minimum
Accuracy
at +25 °C  ± 1 % of range (45 Hz to 65 Hz)
Linearity
10 % to 100 % of range  ± 0.2 % of reading
Noise
   8 mV ac rms (30 A)
   2 mV ac rms (300 A, 3000 A)
Frequency range
   10 Hz to 20 kHz (-3 dB)
Phase error
   < ± 1 º (45 Hz to 65 Hz)
   ± 10 º (at 20 kHz)
Position sensitivity
with cable > 25 mm from the coupling  ± 2 % of range
External field
with cable > 200 mm from the head  ± 1 % of range
Power supply
   2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
Temperature Coefficient
   ± 0.08% of reading per°C
Working voltage
see Safety standards section  600 V AC rms or DC

 

General Specifications
Head Circumference
   610 mm (24 in)
Head cable diameter
   14.3 mm (0.56 in)
Head bend radius
   38.1 mm (1.5 in)
Cable length (head to electronics)
   2 m (6.56 ft)
Output connection
   Molded 4 mm safety plugs (not integrated)
Operating temperature range
   0 °C to +70 °C (32 °F to 158 °F) (head and electronics)
Storage temperature range
   -40 °C to +105 °C (-40 °F to 221 °F) (head)
   -20 °C to +85 °C (-4 °F to 185 °F) (electronics)
Operating humidity
   15 % to 85 % (non-condensing)
Weight
   180 g (6.34 oz) (head)
   190 g (6.70 oz) (electronics)
Safety standards
   EN 61010-1: 2001
   EN 61010-2-032: 2002
   EN 61010-031: 2002
   600 Vrms, Category III, Pollution Degree 2
   Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz.
EMC standards
   EN 61326: 1998 +A1, A2, & A3
Dimensions
HxWxD  116 mm x 68.5 mm x 30 mm (4.56 in x 2.69 in x 1.18 in)