Fluke 750P06Ex Intrinsically Safe Pressure Module 0-100 psi 4558673

Product Code: FLU750P06EX

Price
£2609.00 ex. VAT £3130.80 inc. VAT

Available In 3-7 Days


Add To Favourites
Detailed Description

Precision pressure measurement for 750 and 720 series calibrators

Key Features:

  • Display pressure readings in any of 10 different pressure units you specify in the calibrator setup
  • Rugged urethane molded case protects the module from rough handling and harsh conditions
  • Features internal temperature compensation from 0º C to 50º C for full-accuracy performance
  • Includes NIST-traceable calibration certificate
  • Module can be calibrated locally using the Fluke 700PCK Pressure Calibration Kit, a PC, and a precision pressure source
  • Certified by CSA: I.S. Class I, Div 1, Groups A-D T4, Ta = 0 °C to 50 °C
  • ATEX II  1G EEx ia IIC T4 Compliant.
  • One year warranty

The 750P Series Pressure Modules are the ideal pressure modules to enable gage, differential and absolute pressure measurement with Fluke 750 and 740 series DPCs and 725, 726 MPCs to measure pressure.

  • Up to 0.01 % reference uncertainty
  • 6-month and 1-year specifications
  • Temperature compensated 0 °C to 50 °C
  • Digital communication to calibrators, no analog losses or errors
  • Broad selection of ranges
  • Gage, differential, dual range, absolute and vacuum measurement models
  • Eight (8) Intrinsically Safe models that are certified to:
    - NEC-500: Class I Div 1, Groups A-D, Ga
    - ATEX: II 1 G Ex ia IIC T4 Ga
    - IECEx: Ex ia IIC T4 Ga
    * All certifications: Ta = -10 °C to +50 °C
Fluke 750P Ex Intrinsically Safe Pressure Modules
FLUKE-750P01EX* Pressure Module, 0 to 10 inH2O (0 to 25 mbar), (0 to 2.5 kPa)
FLUKE-750P24EX* Pressure Module, 0 psi to 15 psi (0 to 1 bar), (0 to 100 kPa)
FLUKE-750P05EX* Pressure Module, 0 psi to 30 psi (0 to 2 bar), (0 to 200 kPa)
FLUKE-750P06EX* Pressure Module, 0 psi to 100 psi (0 to 7 bar), (0 to 700 kPa)
FLUKE-750P27EX* Pressure Module, 0 psi to 300 psi (0 to 20 bar), (0 to 2000 kPa)
FLUKE-750P09EX* Pressure Module, 0 psi to 1500 psi (0 to 100 bar), (0 to 10 MPa)
FLUKE-750P29EX* Pressure Module, 0 psi to 3000 psi (0 to 200 bar), (0 to 20 MPa)
FLUKE-750PA4EX* Pressure Module, 0 psi to 15 psi (0 to 1 bar), (0 to 100 kPa)


A complete family of pressure modules

A family of 8 pressure modules covers pressure calibrations in the intrinsically safe category from 25 mbar to 200 bar.

Gage pressure modules have one pressure fitting and measure the pressure with respect to atmospheric pressure. Differential pressure modules have two pressure fittings and measure the difference between the applied pressure on the high fitting versus the low fitting.Each module is clearly labeled for pressure range and media compatibility. All modules include NPT, metric (BSP) and M20 adapters.


Quick and easy measurements

Fluke 750P Series Pressure Modules are easy to use. To measure pressure, connect the pressure module to a pressure source or hand pump and then connect the pressure module cable to the calibrator. Apply pressure from the pressure source and it is displayed digitally on the calibrator. At the touch of a button, the pressure may be displayed in up to 11 different engineering units. When used with the 750 Series Documenting Process Calibrators, pressure readings can be date/time stamped and stored electronically for later retrieval. This saves time, eliminates errors, and supports compliance with quality standards and regulations.

Pressure module performance and technology

Fluke 750P Series pressure modules are highly accurate, with specifications that apply from 0 °C to 50 °C (32 °F to 122 °F), a feature that sets them apart from other pressure calibrators. Many ranges have total uncertainties of 0.04 % of full scale and reference uncertainties of 0.01 % of full scale (see specification table). This performance is possible through the innovative application of mathematics and microprocessor power. Fluke pressure modules have silicon piezo-resistor sensors which consist of a resistive bridge fabricated in a silicon diaphragm.

Pressure applied to the diaphragm causes a change in the balance of the bridge which is proportional to the applied pressure. The bridge balance change is not linear and is very sensitive to temperature. However, since these effects are quite stable with time and with repetitive changes of condition, the sensors are carefully characterized. During manufacture, Fluke pressure module sensors are characterized by reading temperature and pressure at multiple points. A least-squares regression is used to calculate the coefficients of a polynomial expression for pressure.

The coefficients, unique to that pressure module, are stored in the module’s memory. Each module has its own microprocessor, allowing it to run the measurement circuitry and to communicate digitally with a calibrator. When connected to the calibrator, the modules coefficients are uploaded from the pressure module to the calibrator. Then, as pressure measurements are made, raw sensor values for pressure and temperature are digitally loaded to the calibrator, where the raw sensor values and coefficients are manipulated to derive and display the pressure reading.

This innovative technique provides several benefits:

1. Digital communication eliminates errors due to poor connections and electrical interference.
2. The modules are inherently temperaturecompensated from 0 °C to 50 °C (32 °F to 122 °F).
3. The modules are fully interchangeable because all measurements are completed in the pressure module itself and then communicated to the calibrator in digitized form. Modules are calibrated independently of the calibrator, and can be used with any 740, 750 or compatible 720 or 710 series calibrator. Each module has its own serial number to maintain independent traceability.

Sensor protection in isolated modules

Many of these modules (see table) incorporate a stainless steel diaphragm to isolate the sensor. With these modules, any medium that is compatible with stainless steel can be used on the high side of the module.

Rugged construction

A urethane overmolding protects against shock if a module is accidentally dropped and also seals against dirt, dust, and moisture. Pressure connections are ⅛” NPT female connection. A ¼” NPT Male, ¼” BSP/ISO and M20 male adapter are also provided with each pressure module.

 

Convenient setup

A one-meter cable between the pressure module and calibrator reduces the length of connecting tubing to the pressure source. The remote pressure head also provides an extra margin of safety and convenience by removing the calibrator and operator from the pressure source in the event or need for semi-remote measurements.

About Intrinsically Safe Products

Products that appear on this website that are listed as or relate to a classification of intrinsic safety are titled and described according to our best understanding and/or interpretation of the complex and sometimes changing criteria governing such classification as set out by the Health and Safety Executive.
Please note that due to the volatile nature of the intended use of products in this category,  neither UK Test Instruments or Instrument Sales and Services isswww.co.uk can be held responsible for any incident that arises from the purchase or use of any product described within this web site. For more information please visit the health and Safety Executive website with specific regard to Hazardous Area Classification and Control of Ignition Sources.

http://www.hse.gov.uk/comah/sragtech/techmeasareaclas.htm

Fluke 750P Ex Intrinsically Safe Pressure Modules
FLUKE-750P01EX* Pressure Module, 0 to 10 inH2O (0 to 25 mbar), (0 to 2.5 kPa)
FLUKE-750P24EX* Pressure Module, 0 psi to 15 psi (0 to 1 bar), (0 to 100 kPa)
FLUKE-750P05EX* Pressure Module, 0 psi to 30 psi (0 to 2 bar), (0 to 200 kPa)
FLUKE-750P06EX* Pressure Module, 0 psi to 100 psi (0 to 7 bar), (0 to 700 kPa)
FLUKE-750P27EX* Pressure Module, 0 psi to 300 psi (0 to 20 bar), (0 to 2000 kPa)
FLUKE-750P09EX* Pressure Module, 0 psi to 1500 psi (0 to 100 bar), (0 to 10 MPa)
FLUKE-750P29EX* Pressure Module, 0 psi to 3000 psi (0 to 200 bar), (0 to 20 MPa)
FLUKE-750PA4EX* Pressure Module, 0 psi to 15 psi (0 to 1 bar), (0 to 100 kPa)
UK Mainland Order by 2pm for Next Day Delivery*
Under £25.00 £4.50
Over £25.00 FREE

UK Highlands & Islands Order by 2pm for Next Day Delivery*
Under £80.00 £15.00
Over £80.00 FREE

Recently Viewed